Atto-technology 2400C/R/D Manual de usuario Pagina 24

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 50
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 23
19
ATTO Technology Inc. FibreBridge Installation and Operation Manual
3.2 Monitor, Manage Remotely
The Ethernet port provides monitoring and management using the ExpressNAV interface.
Remote system monitoring may be set up through
Remote Management page of the ExpressNAV
interface (see Exhibit 3.0-3) using the Simple Network
Management Protocol (SNMP) or Email.
Various types of problems may create a notification:
Device errors such as medium error, aborted
command and hard error
• Device transitions from online to offline
Critical and warning temperature conditions
Critical and warning voltage conditions
Messages may state that a device is not working, a
medium has an error, or a command has been
stopped.
You may designate which warning level a recipient
receives. For example, a recipient with a critical
severity level only receives critical messages and not
warning or informational messages.
In both monitoring systems, you select the warning
levels for each recipient:
All: all warnings, critical events and
informational messages
Warning: events which are either warnings or
critical events
Critical: only events which are critical
None: no messages are sent
Exhibit 3.0-3 The Remote Management page in the ExpressNAV interface.
Vista de pagina 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 49 50

Comentarios a estos manuales

Sin comentarios