Atto-technology Diamond Storage Array VT-Class Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware Atto-technology Diamond Storage Array VT-Class. ATTO Technology Diamond Storage Array VT-Class User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 96
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Diamond Storage Array
VT-Class
Installation and Operation Manual
© 2005 ATTO Technology Inc. All rights reserved. All brand or product names are trademarks of their
respective holders. No part of this manual may be reproduced in any form or by any means without the
express written permission of ATTO Technology Inc.
2/05 6.4 PRMA-0341-000
Vista de pagina 0
1 2 3 4 5 6 ... 95 96

Indice de contenidos

Pagina 1 - VT-Class

Diamond Storage Array VT-ClassInstallation and Operation Manual© 2005 ATTO Technology Inc. All rights reserved. All brand or product names are tradema

Pagina 2

PrefaceThis guide will take the technology-savvy user through the installation and maintenance of the Diamond Storage Array-VT. The Diamond-VT was des

Pagina 4 - Contents

1 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual1.0 Diamond Storage Array-VT Product OverviewThe Diamond Storage Array-

Pagina 5

2Diamond overview• Aggregated Data Transfer Technology (ADXTJ) for high performance/scalability• Ultra ATA 100 megahertz (Mhz)• RAID Level 10 and R

Pagina 6

3 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual2.0 Diamond-VT Technical OverviewThe Diamond-VT uses Aggregated Data Tr

Pagina 7

4Technical overviewADXT Powers ATA to New LevelsThe original notion of RAID was to build high capacity, reliable storage subsystems using large number

Pagina 8

5 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual3.0 Installation InstructionsIf you are familiar with the Diamond-VT, F

Pagina 9

6Installation6 Follow the screens to find information about the array or to configure the array from the factory-default settings. The Diamond-VT may

Pagina 10 - Disclaimer

7 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual3.1 Diamond-VT ComponentsThe Diamond-VT has been designed to be easy to

Pagina 11

8ComponentsRack mount modelThe system management card is at the left front of the case. At its center is a DB-9 serial RS-232 port which allows a conn

Pagina 13 - SCSI model

9 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual3.2 Diamond-VT Physical SetupThe Diamond-VT is shipped completely assem

Pagina 14 - Midplane

10Physical setupGeneral Instructions 1 Insert the proper connector into the Host Interface Card in the back of the Diamond-VT. (See Connecting a Fibre

Pagina 15 - ADXT Powers ATA to New Levels

11 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual3.2.1 Connecting a Fibre Channel ArrayThe Diamond-VT supports up to tw

Pagina 16 - Commands

12Fibre Channel connectionsExhibit 3.2.1-2 Possible 2 gigabit Fibre Channel physical connections depending on which Fibre Channel connection mode has

Pagina 17

13 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual3.2.2 Connecting a SCSI ArrayThe SCSI Diamond-VT uses a VHDCI connecto

Pagina 19 - Rack mount model

15 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual4.0 Accessing the Diamond-VTCommunicate with the Diamond-VT through th

Pagina 20 - Warranty

16Accessing the arraySNMPSNMP, or Simple Network Management Protocol, is an application layer protocol that allows network devices to exchange managem

Pagina 21 - General Instructions

17 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual4.1 In-band CLI Over Fibre ChannelIn-band Command Line Interface (CLI)

Pagina 22 - CLI: Interface via ASCII

18In-band CLIto an initiator that specifies an incorrect Buffer ID, Mode, Length or Buffer Offset. The Mode is always Data (0x2), the Buffer ID is alw

Pagina 24

19 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual4.2 Serial Port AccessThe Diamond-VT provides remote service operation

Pagina 25 - SCSI connections

20Serial port access

Pagina 26 - 4.0 Accessing the Diamond-VT

21 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual4.3 Ethernet Access: Telnet and SNMP ProtocolsThe optional 10/100 Base

Pagina 27 - Accessing the array

22Ethernet protocols8 Call technical support (see Warranty in the Appendix, page xv) to get the appropriate MIB file for your Diamond-VT.9 For each cl

Pagina 28 - Write Buffer

23 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual5.0 ATTO ExpressNAV: Browser-based InterfaceThe easiest way to communi

Pagina 29 - In-band CLI

24ExpressNAVExhibit 5.0-3 Navigating ATTO ExpressNAV screensSidebar:select theitem youwish toviewSubmit buttonsame as typing allCLI commands andsavec

Pagina 30 - 4.2 Serial Port Access

25 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual5.1 ExpressNAV PagesEach page in the ATTO ExpressNAV interface provide

Pagina 31 - Serial port access

26ExpressNAVLogical Units Displays information on the logical units which have been configured and allows you to change the status from online or offl

Pagina 32 - Summary of CLI

27 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual6.0 CLI: Interface via ASCII-based CommandsThe command line interface

Pagina 33 - Ethernet protocols

28Command Line InterfaceExhibit 6.0-3 CLI commands returns may be terse (short) or verbose (with parameter names and details of results). Zoning comm

Pagina 34 - Navigating ExpressNAV

ATTO Technology Inc.ContentsPreface1.0 Diamond Storage Array-VT Product Overview ...1Diamond-VT featuresFibre Channel model

Pagina 35 - ExpressNAV

29 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual6.1 Summary of CLI CommandsA summary of the Command Line Interface com

Pagina 36 - 5.1 ExpressNAV Pages

30CLI indexIdeWriteCache enabled set idewritecache disabled42Info Info39InquiryData InquiryData 11456 124345 1.0 11242 14564 242IPAddress 10.0.0.1 set

Pagina 37

31 ATTO Technology Inc. Diamond Storage Array Installation and Operation ManualSystemSN get systemsn32TapeDriveInfo TapeDriveInfo40TapeVolumeBlockSize

Pagina 38

32Diamond Storage Array Installation and Operation Manual6.2 General Use CommandsThe following commands, listed alphabetically, describe or perform g

Pagina 39 - Command Line Interface

33 ATTO Technology Inc.6.3 Ethernet CommandsEthernet configuration commands configure the Ethernet and TCP/IP parameters for the Diamond Storage Arra

Pagina 40 - 6.1 Summary of CLI Commands

34Diamond Storage Array Installation and Operation ManualSNMPTrapsEnables or disables SNMP traps.Default: disabledSet syntax: set SNMPTraps [enabled|d

Pagina 41 - CLI index

35 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual6.4 Fibre Channel Configuration CommandsThe Fibre Channel ports are co

Pagina 42

36CLI: Fibre ChannelFcPortListLists the status of all available Fibre Channel ports. Immediate command: FcPortListFcPortNameReturns the Fibre Channel

Pagina 43 - 6.2 General Use Commands

37 ATTO Technology Inc.6.5 Serial Port Configuration CommandsThe serial port configuration may be customized by using the following commands:SerialPo

Pagina 44 - 6.3 Ethernet Commands

38CLI: maintenance6.6 Maintenance Services CommandsMaintenance commands allow updating and maintenance of the Diamond-VT.FcScsiBusyStatusYou may set

Pagina 45

Diamond Storage Array Installation and Operation Manual5.0 ATTO ExpressNAV: Browser-based Interface ...23Browser compatibi

Pagina 46

39 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual6.7 Diagnostic CommandsDiagnostic commands provide information or diag

Pagina 47

40CLI: diagnosticsPowerAudibleAlarmSilences the audible alarm for a current power supply failure. The alarm will be activated on the next power failur

Pagina 48 - ATTO Technology Inc

41 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual6.8 Drive Management CommandsThe Diamond Storage Array ATA drives may

Pagina 49 - CAUTIONCAUTION

42CLI: configure drivesDriveWipeInitializes a drive: wipes it of all data. Drive must be offlineSet syntax: DriveWipe [Destination Sled] [Dest Drive]

Pagina 50 - 6.7 Diagnostic Commands

43 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manualsoftware. The remaining four characters will be entered by the system a

Pagina 51

44CLI: configure drivesRebuildPrioritySets the priority of a RAID Level 5 or 10 rebuild. If you select High priority, rebuild I/O requests are impleme

Pagina 52

45 ATTO Technology Inc. Diamond Storage Array Installation and Operation ManualZoneClearAllRemoves all entries from the Planned Zone Configuration.Rem

Pagina 53 - Default: 4

46CLI: configure drives

Pagina 54

47 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual7.0 Configuring the Diamond-VT The Diamond-VT can be configured as RAI

Pagina 55 - Default: disabled

48Configure drivesAdvanced CLI configuration page of the ExpressNAV interface. Zoning supports security by granting or denying access between initiato

Pagina 56

ATTO Technology Inc.6.4 Fibre Channel Configuration Commands ...35FcConnModeFcDataRateFcFairArbFcFrameLengthFcFullDuplexFcHar

Pagina 57 - CLI: configure drives

49 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual7.1 Virtual TapeWhen the Diamond-VT is configured as a Virtual Tape, i

Pagina 58 - Optional Hot Spare Sled

50Hot swap spare sled7.2 Optional Hot Spare SledTo maintain array up time with minimal risk of data loss, individual sleds which fail may be replaced

Pagina 59 - Configure drives

51 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual7.3 ZonesZoning is a collection of related Diamond-VT capabilities sup

Pagina 60 - 7.1 Virtual Tape

52Zonesthe Active configuration will be copied into the Planned configuration.To determine what is in the Planned configuration, type ZoneInfo Planned

Pagina 61 - 7.2 Optional Hot Spare Sled

53 Diamond Storage Array Configuring ZoningCAUTIONCAUTIONBe careful when changing Diamond-VT zoning configurations. Internal validation logic cannot d

Pagina 62 - 7.3 Zones

54ZonesErrorsZone definition tables: The Zone commands manage entries in the Zone definition tables which manage the overall zoning process. Definiti

Pagina 63 - Status and Sense Data

55 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual8.0 Updating FirmwareEngineers, technicians and/or system administrato

Pagina 64 - Configuring Zoning

56Update firmware3 Copy the latest Diamond-VT image file (“...”.ima) onto the host computer and note its directoryc:\diamond\flash\“...”.ima4 Change d

Pagina 65

57 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual9.0 Diagnostics, Upgrade and MaintenanceThe Diamond-VT provides a numb

Pagina 66 - 8.0 Updating Firmware

58Monitoring, reportingtemperature warning alarm will report OK during normal operating conditions.In an abnormal operating condition, such as blower

Pagina 67 - Resetting Defaults

Diamond Storage Array Installation and Operation ManualTemperatureVirtualDriveInfoZoneInfoZoneState6.8 Drive Management Commands ...

Pagina 68 - Accessing the Diamond-VT

59 Diamond Storage Array an error code, please provide both the first and second blink code values.During a fault condition, more detailed informatio

Pagina 69 - Monitoring, reporting

60Monitoring, reporting

Pagina 70 - 59 Diamond Storage Array

61 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual9.1 TroubleshootingThe Diamond-VT provides a number of indicators to i

Pagina 71

62Troubleshooting• Follow the instructions in the appropriate chapters of this manual to remove, replace and reconfigure the drive such as Hot Swap O

Pagina 72 - 9.1 Troubleshooting

63 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual9.2 Resetting DefaultsResetting the Diamond-VT to defaults will not al

Pagina 73

64Reset defaultsExhibit 9.2-2 Configurations which will be changed during a RestoreConfiguration commandCommand DefaultReset if default chosen Reset

Pagina 74 - 9.2 Resetting Defaults

65 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual9.3 Rebuilding RAID Level 5 and 10 ConfigurationsIf a sled must be rem

Pagina 75 - Reset defaults

66rebuilding RAIDTo synchronize mirrored drives manuallyThe most efficient method to synchronize Virtual Tape configurations is to enable Hot Spares o

Pagina 76

67 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual10.0 Hardware MaintenanceThe disk drive sleds, blower assemblies, powe

Pagina 77

68Hardware maintenanceExhibit 10-2: Above, disk drive sled partially pulled out of the Diamond Storage Array. Bottom left, top of disk drive sled. Bo

Pagina 78 - 10.0 Hardware Maintenance

ATTO Technology Inc.7.0 Configuring the Diamond-VT ...47RAID Level 10RAID Level 5Virtual Tape

Pagina 79 - Hardware maintenance

69 ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual10.1 Hot Swap Operating InstructionsTo maintain array up time, individ

Pagina 80

70Hot swap hardwarePower SuppliesCAUTIONCAUTIONDo not leave empty openings on the front or rear of the Diamond-VT under any circumstances. Empty openi

Pagina 81 - Blower Assemblies

A-i ATTO Technology Inc. Diamond Storage Array Installation and Operation ManualAppendix A GlossaryThe following terms are only a few examples of the

Pagina 82 - Appendix A Glossary

A-iiAppendixF_port A port in the FC fabric where a N_port may attachFC-AL Fibre Channel Arbitrated Loop: an FC network in which up to 126 systems and

Pagina 83 - Appendix

A-iii ATTO Technology Inc. Diamond Storage Array Installation and Operation ManualAppendix B ATA Disk TechnologyATA is the dominant disk drive techno

Pagina 84 - Disk features and standards

A-ivAppendix C Information Command ReturnsDriveinfo Sled Capacity Errors TYPE ...VDID Capacity Errors TYPE VDID === ====== ..===== ===== ==

Pagina 85 - Driveinfo

A-v ATTO Technology Inc. Diamond Storage Array Installation and Operation ManualRead 00000000 00000000Write 00000000 00000000Errors 00000000Lun

Pagina 86

A-viWrite 00000000 00000000Errors 00000000LunInfo for a RAID5 1 configurationLUN TYPE State Capacity Errors SerialNumber=== ====

Pagina 87

A-vii ATTO Technology Inc. Diamond Storage Array Installation and Operation ManualVolume Partition Total % Capacity Write

Pagina 89

Diamond Storage Array Installation and Operation ManualAppendix A Glossary ...

Pagina 90 - Symmetric Model

A-ix ATTO Technology Inc. Diamond Storage Array Installation and Operation ManualAppendix D Sample Zoning Command SequencesFirst time configuration (

Pagina 91 - Asymmetric Model

A-xAppendixAsymmetric Model3 hosts, 1 metadata controller (also a host), RAID 5 with 3 LUNs. All zone commands except ZoneCommit affect only the plann

Pagina 92

A-xi ATTO Technology Inc. Diamond Storage Array Installation and Operation ManualCombined Symmetric/Asymmetric ModelMany hosts. All zone commands exce

Pagina 93 - Appendix E Specifications

A-xiiAppendixAppendix E SpecificationsEnvironmental and physical• Humidity: 10-85% non-condensing• Normal operating temperature at sea level: 5-40o

Pagina 94 - Appendix F Product Safety

A-xiii ATTO Technology Inc. Diamond Storage Array Installation and Operation ManualAppendix F Product SafetySafe handling of the Diamond-VT will help

Pagina 95 - Appendix G Part numbers

A-xivAppendix G Part numbersEach Diamond-VT has a master part number to identify it. The floor model base number is on the side of the unit. The rack

Pagina 96 - Appendix H Warranty

A-xv ATTO Technology Inc. Diamond Storage Array Installation and Operation ManualAppendix H Warranty Manufacturer limited warrantyManufacturer warran

Comentarios a estos manuales

Sin comentarios