Atto-technology Diamond Storage Array VT-Class Manual de usuario Pagina 28

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 96
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 27
17
ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual
4.1 In-band CLI Over Fibre Channel
In-band Command Line Interface (CLI) configures and manages the Diamond-VT using SCSI-based
CLI commands over a Fibre Channel port connection.
In-band CLI allows a programmer to configure
the Diamond-VT while it is moving data. Using a
programmers interface, CLI commands as
described previously in this manual may be
implemented.
In-band CLI is implemented as part of LUN 0. It
uses a different LUN than the Diamond-VT, and
reports as a Storage Enclosure Services (SES)
device (device type 0x0D).
LUN 0 is visible on all Fibre ports but is actually
a single unit. The default value for LUN 0 is 0x00.
LUN 0 must be reserved for each Write
Buffer/Read Buffer pair, using the SCSI Reserve
command to insure integrity of the in-band CLI
session.
1 An initiator (host) sends a SCSI Reserve
command to LUN 0.
If LUN 0 is not reserved by another initiator,
LUN 0 is now reserved and ready to begin a
new CLI session.
If the Diamond-VT configuration is reserved
by a different CLI session (i.e. serial or
Telnet), the in-band session is not allowed to
modify the Diamond-VT configuration. If you
try, the results buffer of LUN 0 returns:
Process X has the configuration
reserved.
ID of this session = Y
Ready.
2 The initiator issues a SCSI
Write Buffer
command to LUN 0. A
Write Buffer
command
must be accompanied by an ASCII buffer
representing the CLI command string such as
set DiamondName Omega1
LUN 0 executes the command line and create
feedback in the form of ASCII characters into a
buffer. This buffer is 8 KB and circular. Retrieve
the results by issuing a Read Buffer command
before issuing another Write Buffer command.
3 A subsequent Write Buffer command
executes the new command line and overwrites
the previous results in the buffer with new
results.
4 LUN 0 can be released by issuing a SCSI
Release command to the LUN after each
Write/Read Buffer pair, or multiple Write/Read
Buffer pairs.
I/O details
The buffer sent to the Services LUN during the
data out phase of a Write Buffer command must
be:
• ASCII data
maximum 80 bytes length
terminated with either a carriage return
character (0x0D), line feed character (0x0A) or
NULL character (0x00)
Characters following the first carriage return
character, line feed character or NULL character
are ignored.
The buffer retrieved from the Services LUN
during the data-in phase of a
Read Buffer
command:
• ASCII data
8 KBytes (8192 bytes) in length
terminated with a NULL character (0x00)
Characters following the NULL character are
meaningless.
A CHECK_CONDITION,
INVALID_PARAMETER_IN_CDB is returned
Initiator (Host) Diamond-VT
Reserve LUN 0 return: “ok”
Write Buffer
LUN 0
bid ‘AA
“get Temperature”
executes the CLI
command, stores
output in buffer
Read Buffer
LUN 0
bid ‘AA
return:”Temperature=28
C\r\n\Ready.\r\n\0
Release LUN 0 return: “ok”
Vista de pagina 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 95 96

Comentarios a estos manuales