ATTO Technology H608 Manual de instalación

Busca en linea o descarga Manual de instalación para Redes ATTO Technology H608. ATTO Technology H608 Installation manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 124
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
ATTO Utilities
Installation and Operation Manual
ATTO ConfigTool for Windows®, Linux® and Mac OS® X
ATTO BIOS Utilities
ATTO Utilities for Windows
Vista de pagina 0
1 2 3 4 5 6 ... 123 124

Indice de contenidos

Pagina 1 - ATTO Utilities

ATTO Utilities Installation and Operation ManualATTO ConfigTool for Windows®, Linux® and Mac OS® XATTO BIOS UtilitiesATTO Utilities for Windows

Pagina 2 - ATTO Technology, Inc

5 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Navigating the ConfigToolCAUTIONCAUTIONSave system data prior to installing or

Pagina 3 - Contents

95 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual• Stripe Group: If the test drive is a stripe group, select its name from the

Pagina 4

96 3.3 FC LUN Masking UtilityATTO storage controller drivers allow you to select which devices and Logical Unit Numbers (LUNs) on a SAN are visible

Pagina 5

97 ATTO Technology Inc. ATTO Utilities Installation and Operation ManualSaving and applying your changes1 Click the Save Changes button on the bottom

Pagina 6 - 1.0 ATTO ConfigTool

98 3.4 SNIA FC Storage Controller APIAPI, or Application Programming Interface, is a set of commands used by an application directing the operating

Pagina 7 - Installation

99 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual 3.5 Domain Validation TestingDomain Validation tests the physical connectio

Pagina 8

100Exhibit 3.5-1 The Domain Validation Utility page.

Pagina 9 - Using the ATTO ConfigTool

101 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual 3.6 ExpressPCI SCSI Setup UtilityThe ExpressPCI Setup Utility changes the

Pagina 10 - Navigating the ConfigTool

102 3.7 Troubleshoot ATTO Utilities for WindowsThe following suggestions may help if you are having problems.• Using the Device Manager, ensure all

Pagina 11 - Select a Channel

i ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Appendix A CLI provides an ASCII-based interfaceThe RAID CLI tab in the ATTO C

Pagina 12 - System Reboot

iiExhibit A-1 Symbols, typefaces and abbreviations used to indicate functions and elements of the command line interface used in this manual.CLI err

Pagina 13

6Select a Storage ControllerThe following tabs display in the Configuration Options window when you select a specific storage controller in the Devic

Pagina 14 - Exhibit 1.0-4 The Flash tab

iii ATTO Technology Inc. ATTO Utilities Installation and Operation Manual ERROR Invalid number of Partitions specifiedERROR Invalid Span Depth specifi

Pagina 15 - CAUTIONCAUTION

ivClearEventLog cleareventlogDateDeleteScheduledTasksDisplayScheduledTasksDriveAssureReport driveassurereport groupname1DriveHealth disabled set driv

Pagina 16

v ATTO Technology Inc. ATTO Utilities Installation and Operation Manual RGCancelAddStorage rgcanceladdstorage groupname1RGCancelMediaScanRGCommit rgco

Pagina 17 - FastFrame NVRAM Settings

viCLI command explanationsCommand Line Interface commands are listed alphabetically with explanations of what they are used for, their defaults and s

Pagina 18 - ExpressPCI NVRAM Settings

vii ATTO Technology Inc. ATTO Utilities Installation and Operation Manual BlockDevScan (Immediate, Disabled on Error) BlockDevScan lists all currently

Pagina 19

viiiDriveHealthDisplay (Immediate, Disabled on Error) Retrieves and displays S.M.A.R.T. data from SATA disk drives, and MEDIUM DEFECT and INFORMATION

Pagina 20

ix ATTO Technology Inc. ATTO Utilities Installation and Operation Manual HSAdd (Immediate) Assigns a Block Device to the Hot Spare pool.Usage: HSAdd [

Pagina 21 - Spinup Delay

xPartitionWriteCache Enable RAID internal Write Cache for higher write performance with a small risk of data loss after a system failure. Disable RAI

Pagina 22 - 1.4.1 RAID Configuration

xi ATTO Technology Inc. ATTO Utilities Installation and Operation Manual RGAutoRebuild RGAutoRebuild enables and disables Auto-Rebuild functionality f

Pagina 23 - Setting up DVRAID

xiiRGMediaScanErrorReport (Immediate, Disabled on Error) Displays error statistics for either a single RAID Group or all RAID Groups in the system.Us

Pagina 24 - Customizing a RAID setup

7 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Driver updateA storage controller driver can be installed or upgraded on a hos

Pagina 25

xiii ATTO Technology Inc. ATTO Utilities Installation and Operation Manual RGSectorSize Set or get the sector size of the specified RAID Group. The de

Pagina 26

xivSES (OEM Configurable, Disabled on Error) SES enables support for SES enclosures that have been discovered by the system.Usage: set SESget SES [en

Pagina 27 - Modifying RAID Groups

xv ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Time (Disabled on Error) Time sets/displays the current time in 24 hour forma

Pagina 28 - Replacing a faulted drive

xviAppendix B GlossarySome terms used in the Fibre Channel industry are defined below. More information is available through the ATTO Technology web

Pagina 29 - Setup RAID Notification

xvii ATTO Technology Inc. ATTO Utilities Installation and Operation Manual L_port A port in an arbitrated loop, either a NL_port or a FL_port.LED Ligh

Pagina 30

8Exhibit 1.0-2 The Basic Info tab when you choose a Host from the Device Listing.Exhibit 1.0-3 The Basic Info tab when a storage controller is chos

Pagina 31

9 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Exhibit 1.0-4 The Flash tab.Exhibit 1.0-5 The NVRAM information page.

Pagina 32 - Identifying Drives

10 1.1 Celerity and ThunderLink FC NVRAM SettingsThe settings in the NVRAM tab vary depending upon the selected Celerity or ThunderLink Fibre Channel

Pagina 33 - Monitoring Health

11 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Connection Mode OptionsChoices: AL, PTP, AL Preferred, PTP PreferredDefault:

Pagina 34 - Checking S.M.A.R.T. Status

12 1.2 FastFrame NVRAM SettingsThe settings in the NVRAM tab vary depending upon the selected adapter and the operating system. Settings unsupported

Pagina 35

13 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual 1.3 ExpressPCI NVRAM SettingsThe settings in the NVRAM tab vary depending up

Pagina 36 - S.M.A.R.T. Notifications

14Specified TargetChoices: 0 to 15 or 0 to 7 if Wide ID is disabledDefault: 0Specifies the target ID to which settings are applied.LUNs Choices: Dis

Pagina 37 - Test Drive Performance

ATTO Technology, Inc.155 CrossPoint ParkwayAmherst, New York 14068 USAwww.attotech.comTel (716) 691-1999Fax (716) 691-9353 Sales support: sls@attotech

Pagina 38

15 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual 1.4 ExpressSAS, ThunderLink SH and ThunderStream SC NVRAM SettingsThe setti

Pagina 39 - RAID Media Scan Feature

16Spinup Delay Choices: 0-20 secondsDefault: 0Specifies the number of seconds each SAS PHY waits for disk drives to spin up.Multiplexing (6Gb RAID st

Pagina 40 - Starting a Media Scan

17 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual 1.4.1 RAID ConfigurationExpressSAS RAID and ThunderStream SC storage contro

Pagina 41 - Media Scan Status

18Preliminary Steps1 Locate the ConfigTool icon in the folder you created during installation (Refer to ATTO ConfigTool on page 1).2 Double-click on

Pagina 42 - Viewing the Scan Report

19 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Exhibit 1.4.1--2 The DVRAID wizard automatically sets up the number of RAID

Pagina 43

20• SpeedRead, Auto-Rebuild and Rebuild Priority: refer to Change RAID group properties on page 23 for specific information on these parameters.• S

Pagina 44 - Scheduling Media Scan

21 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Exhibit 1.4.1--3 Selecting the options to configure the new RAID group.Exhib

Pagina 45 - Viewing Scheduled Tasks

22Creating a Hot Spare PoolIf a member of a RAID group becomes degraded or fails, you lose some redundancy in your RAID group until a new member is r

Pagina 46 - Definitions

23 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Change RAID group propertiesA RAID group has properties that are specific to

Pagina 47

24Enable Auto-RebuildA faulted drive is automatically replaced if Auto-Rebuild is enabled and a suitable unallocated disk is available. Suitable unal

Pagina 48 - Failure Scenario Table

Contents 1.0 ATTO ConfigTool ...1Pre-InstallationInstallation

Pagina 49 - Failed Drive

25 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual LoggingThe ATTO ConfigTool Service outputs RAID events and other useful infor

Pagina 50

26Exhibit 1.4.1--7 The Notifications tab in the ATTO ConfigTool.Exhibit 1.4.1--8 Mute Audible Alert (Windows) Exhibit 1.4.1--9 Mute Audible Alert

Pagina 51 - Recovering from Failed Drives

27 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Using SCSI Enclosure Services (SES)SAS/SATA drive enclosures may provide a SC

Pagina 52 - Recovery from Failed Rebuild

28Monitoring HealthThe ATTO SAS/SATA RAID storage controller performs Enclosure Health Monitoring automatically when an SES device is present. The RA

Pagina 53 - RAID Group goes ONLINE

29 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Monitoring S.M.A.R.T. DataSelf-Monitoring, Analysis and Reporting Technology,

Pagina 54

30• Use the Refresh button to query the drive for the latest values. If any values are different from the most recent record, a new record is created

Pagina 55

31 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Exhibit 1.4.1--12 S.M.A.R.T. Status box with classification types.S.M.A.R.T.

Pagina 56 - Command Line Interface

32Test Drive PerformanceThe performance testing feature in the ATTO ConfigTool records the performance level of a drive in a RAID group under an I/O

Pagina 57 - SESIdentify DRIVE

33 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Exhibit 1.4.1--13 Detail of the Attached Drives window and the Performance d

Pagina 58 - BlockDevIdentify

34RAID Media Scan FeatureThe Media Scan feature scans disk drives for media errors and parity errors. All media errors are counted and fixed. All par

Pagina 59

1.4.2 SNMP Configuration ...56DefinitionsDetailsConfiguration OptionsControl Bu

Pagina 60 - CacheAssure™

35 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Starting a Media Scan1 Select the ExpressSAS RAID or ThunderStream SC storage

Pagina 61 - 1.4.2 SNMP Configuration

36Media Scan StatusThe Media Scan starts as soon as the menu item is selected. The Attached Drives panel displays a rotating icon next to each drive

Pagina 62 - SubAgent Mode

37 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Viewing the Scan Report1 Select the ExpressSAS RAID or ThunderStream SC stora

Pagina 63 - Configuration Options

38Pausing or Resuming Media ScanMedia Scan for a parity RAID group can be paused, resumed and cancelled. The Configuration Tool provides menu items t

Pagina 64 - Control Buttons

39 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Scheduling Media ScanMedia Scan for a parity RAID group can be scheduled to o

Pagina 65 - Troubleshooting

40Viewing Scheduled TasksThe Configuration Tool contains a Task tab for each RAID storage controller present in the system. The tab contains a table

Pagina 66 - Exhibit 1.4.2--1 Panel Image

41 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Data Recovery for OFFLINE RAID GroupsATTO SAS/SATA RAID storage controllers u

Pagina 67

42Exhibit 1.4.1--16 RAID Member Status ValuesRebuild Status ValuesOk Data is up to dateFaulted The operation was stopped due to an errorHalted The o

Pagina 68 - 1.5 Virtual Port Management

43 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Failure Scenario TableRAID Groups cannot be accessed normally when their memb

Pagina 69 - Creating a Virtual Port

44Identifying Failed DrivesIf a failed drive is in an enclosure that supports SES (SCSI Enclosure Services), the drive's Fault LED should be bli

Pagina 70 - Deleting a Virtual Port

Appendix A CLI provides an ASCII-based interface... iCLI error messagesCLI summaryCLI command explanationsAppe

Pagina 71 - NPIV Troubleshooting

45 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual By double-clicking the RAID Group line, each RAID Member and its status is di

Pagina 72

46The member drive can be physically identified, in its enclosure, by right-clicking in the Attached Drives list and selecting Locate (See Exhibit 1.

Pagina 73

47 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Recovery ModeSometimes, despite careful operation and maintenance, drives wil

Pagina 74

48Exhibit 1.4.1--28 Enable Rebuild RecoveryThe RAID Group status will change from Offline to Degraded. The Rebuild status will change from Rebuildin

Pagina 75 - Feature bounds checking

49 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Serious Disk Failure During Rebuild - Using “Extreme” Mode Exhibit 1.4.1--30

Pagina 76 - Accessing the SAS utility

50Exhibit 1.4.1--38 Enable Basic Recovery ModeThe RAID Group status will change from Offline to Recovery (Basic). Once you enter Recovery Mode, use

Pagina 77

51 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual File System Repair ToolsWhen a RAID array has been made accessible by setting

Pagina 78 - FC BIOS Configuration Utility

52RGdisplayThis is the RAID Group display command. Use this command to display all RAID Groups and their statuses.NoteIf rgdisplay shows a RAID Group

Pagina 79

53 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual BlockDevIdentifyUse this command to blink the activity LED for the drive (if

Pagina 80 - Configuring adapter channels

54Display the RAID Group to see the results:Display the RAID Group members to see the results:Once as much data as possible is retrieved from the dri

Pagina 81 - SCSI device settings

1 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual 1.0 ATTO ConfigToolThe ATTO ConfigTool is a utility program that displays in

Pagina 82 - Tagged Command Queuing

55 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual CacheAssure™CacheAssure is available on ATTO’s ExpressSAS 6Gb/s RAID storage

Pagina 83 - ExpressSAS BIOS Utility

56 1.4.2 SNMP ConfigurationSNMP is a standard network protocol that provides the ability to monitor SNMP enabled systems from anywhere on the netwo

Pagina 84 - Default: 8 Internal

57 ATTO Technology Inc. ATTO Utilities Installation and Operation ManualSubAgent ModeThis mode of operation relies on the operating system's SNMP

Pagina 85 - Create a RAID group

58Disabled ModeThis mode disables the operation of the ATTO SNMP agent. Any network ports it has open to support SNMP are closed, making it inaccess

Pagina 86

59 ATTO Technology Inc. ATTO Utilities Installation and Operation ManualSend Authentication TRAPWhen checked, the agent will send a TRAP to the config

Pagina 87 - ExpressSAS EFI Utility

60TestThis button will validate the settings displayed on screen, and then send a warm Start trap to each of the displayed trap destinations as if t

Pagina 88 - Configuring Adapter Settings

61 ATTO Technology Inc. ATTO Utilities Installation and Operation ManualExhibit 1.4.2--1 Panel ImageExhibit 1.4.2--2 Community Image

Pagina 89 - Displaying the Drive List

62Exhibit 1.4.2--3 Edit Trap Image

Pagina 90

63 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual 1.5 Virtual Port ManagementThe ConfigTool provides the ability to manage virt

Pagina 91

64StatusThe NPIV status of the selected channel. This will be one of:• OK: Virtual ports can be created on this channel.• Disabled: NPIV is current

Pagina 92

2InstallationThe ATTO ConfigTool includes two components: a GUI Application and a system service. Either, or both, of these components can be install

Pagina 93 - Create a RAID Group

65 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual Exhibit 1.5-2 The “Create Virtual Ports” windowThe ConfigTool will attempt t

Pagina 94

66Exhibit 1.5-4 The “Delete Confirmation” window• Click Yes in the Delete Confirmation window to delete the port. If the virtual port is deleted suc

Pagina 95 - Exhibit 2.4-11 on page 91

67 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual a. Changes to NVRAM settings require a system restart to take effect.b. Refer

Pagina 96

68Error MessageOccurs On...Explanation Recommended Action“Unsupported function”Create/DeleteThe driver received a NPIV request that it does not suppo

Pagina 97 - ConfigTools

69 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual a.Changes to NVRAM settings require a system restart to take effect.b. Refer

Pagina 98 - Using Alamode

70 1.6 Troubleshoot the ATTO ConfigToolYou may see an error message informing you about an unexpected event or incorrect information discovered by t

Pagina 99 - 3.2 ATTO Disk Benchmark

71 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual 2.0 BIOS Configuration UtilityThe BIOS driver for all ATTO storage controlle

Pagina 100

72Common BIOS Configuration Utility functionsSelectable Boot DeviceAllows you to select a disk drive or stripe group from which the system BIOS load

Pagina 101 - 3.3 FC LUN Masking Utility

73 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual 2.1 FC BIOS Configuration UtilityDefault NVRAM settings work for most applic

Pagina 102

74Boot DriverChoices: enabled, scan only, disabledDefault: disabledIf enabled and disk drives or a bootable CD are detected during the bus scan, the

Pagina 103

3 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual To install the Full Application or Application Only:3 Run the ConfigTool_xxx.b

Pagina 104 - Running the SCSI Application

75 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual 2.2 SCSI BIOS Configuration UtilityThe default NVRAM settings work for most

Pagina 105

76Quick Arbitrate & Select (Ultra320 only)Choices: disabled, enabledDefault: enabledReduces the time required to gain control of the SCSI bus if

Pagina 106 - Modifying NVRAM settings

77 ATTO Technology Inc. ATTO Utilities Installation and Operation ManualSync OffsetChoices: 1-127Default: 127CAUTIONCAUTIONThe default values offer th

Pagina 107

78 2.3 ExpressSAS BIOS UtilityThe BIOS driver for the ATTO ExpressSAS storage controllers has a built-in BIOS Utility which manages the adapter and

Pagina 108 - Appendix A

79 ATTO Technology Inc. ATTO Utilities Installation and Operation ManualHeartbeatChoices: enabled, disabled Default: enabled When enabled, requires th

Pagina 109 - CLI error messages

80View Selected RAID GroupType Enter to display more information about the highlighted RAID group. If a RAID group is rebuilding, the command displa

Pagina 110 - CLI summary

81 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual 2.4 EFI Configuration UtilityThe EFI drivers for ATTO Celerity 8Gb and Expre

Pagina 111

82ExpressSAS EFI UtilityThe EFI driver for ATTO ExpressSAS storage controllers has a built-in EFI Utility which manages the adapter and the devices c

Pagina 112

83 ATTO Technology Inc. ATTO Utilities Installation and Operation ManualConfiguring Adapter SettingsThe Configure Adapter Settings menu displays infor

Pagina 113 - CLI command explanations

84Exhibit 2.4-3 The Display Drive List MenuDisplaying the Drive List (ExpressSAS RAID adapter only)Selecting the Display Drive List menu item displa

Pagina 114

4Using the ATTO ConfigToolTo use the ATTO ConfigTool, locate and double-click the application icon. The main page has three windows: Device Listing,

Pagina 115

85 ATTO Technology Inc. ATTO Utilities Installation and Operation ManualExhibit 2.4-4 The Display Drive List MenuThe Display Drive List menu highligh

Pagina 116

86Exhibit 2.4-5 The Drive Details WindowConfiguring RAID groups (ExpressSAS RAID adapter only)Selecting the Configure RAID Groups menu displays a li

Pagina 117

87 ATTO Technology Inc. ATTO Utilities Installation and Operation ManualExhibit 2.4-6 The Configure RAID Groups MenuThe Configure RAID Groups menu hi

Pagina 118

88Exhibit 2.4-7 The Group Details WindowCreate a RAID GroupSelecting Create RAID Group starts a wizard. See Exhibit 2.4-8.Exhibit 2.4-8 The Create

Pagina 119

89 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual1 Type a RAID group name. The name must be unique and no more than 14 characte

Pagina 120

90Exhibit 2.4-10 After adding drives to a new RAID Group10 Type Enter to create the RAID group. See Exhibit 2.4-11 on page 91.

Pagina 121

91 ATTO Technology Inc. ATTO Utilities Installation and Operation ManualExhibit 2.4-11 Group creation finishedCAUTIONCAUTIONA rebuild occurs after cr

Pagina 122 - VirtualDriveInfo (Immediate)

92 3.0 ATTO Utilities for WindowsThe ATTO Utilities for Windows is a collection of programs which provide adapter management, device management and

Pagina 123 - Appendix B Glossary

93 ATTO Technology Inc. ATTO Utilities Installation and Operation Manual 3.1 Configure Mode Pages: Alamode UtilityAlamode is a Windows utility to opt

Pagina 124

94 3.2 ATTO Disk BenchmarkThe ATTO Utilities for Windows suite includes a utility to measure peak and sustained throughput for disk reads and disk w

Comentarios a estos manuales

Sin comentarios